RTS KP95 Manual do Utilizador Página 53

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 90
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 52
Advant Controller 31 / Issued: 07.99
7 Hardware 07 KP 93 R1161
8 .3
07 KT 94
Basic Unit
Advant Controller 31
Advant Controller 31
07 KP 93
RUN
ERR
Supp.
2
3
4
1
LED
Do not connect
Do not
connect
Do not connect
1.3.5 Networking interface
The communication processor can be connected to AC31
basic units of the 90 series which have a networking in-
terface. The housing of the communication processor is
40-pole ribbon cable
Connection part
Note: Attachment and disconnection of units on the networking
interface may only be performed when all supply voltages
are switched off.
Fig. 8: Example: Connecting 07 KP 93 with 07 KT 94
Mounting the expansion housing
1. Detach the cover on unit 07 KT 94 from the network-
ing interface.
2. Plug the socket strip of the 40-pole ribbon cable se-
cured to the 07 KP 93 onto the networking connector
of the 07 KT 94.
3. Place both units on a level surface and slide them to-
gether so that they engage.
4. Slide in the connection part to fix the housing in posi-
tion.
9
connected to the housing of the AC31 basic unit by a snap-
fit connection. The electrical connection is via a 40-pole
ribbon cable with socket connector, soldered onto the
07 KP 93 side.
Vista de página 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 89 90

Comentários a estes Manuais

Sem comentários