RTS RVON-I/O Manual do Utilizador Página 27

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 60
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 26
21
8. At the prompt, type d/jointfilesconvert/320764/bgcmd to access the debug command screens.
9. Press Enter.
An MXP prompt appears.
10. At the MXP prompt, type set rvon ip_addr 10.3.210.12 (this IP Address is for example purposes only).
11. Press Enter.
The IP Address is set for the RVON-I/O.
12. Set the Netmask.
13. At the MXP prompt, type Activate.
RVON-I/O will reset itself to the new IP Address. The current telnet session becomes invalid.
Configure the IP Address Using the Serial Debug Port
NOTE: In order to use the Serial Debug Port to set the IP Address for your RVON-I/O, you must know the intended IP
Address. Also, you must make sure DIP switch 2 is not enabled (CLOSED).
The following instructions will show you how to access the Serial Debug Port screens and show you how to configure the IP
Address for the RVON-I/O
To configure the IP Address for the RVON-I/O, do the following:
1. Connect the PC’s COM port to the RVON-I/O’s serial connector.
2. Run a HyperTerminal program.
The window provided Hyper Terminal is located at Start Programs>Accessories>Communications >HyperTerminal.
3. At the prompt, type d/jointfilesconvert/320764/bgcmd.
Figure 5.
Vista de página 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 59 60

Comentários a estes Manuais