32
NOTE: The extra port 9 only is currently applicable to the ADAM Intercom System setup.
Set Panel
Set Panel sets the address at which the RVON-I/O will respond to polls sent by the Intercom. If the RVON-I/O is connecting
to a Zeus or AIO-8, you must set a Panel Poll ID. The panel poll ID is the data port address from which it communicates.
Also, the panel poll ID is only used in remote mode.
Because the Zeus and AIO-8 share their data across 8 ports, they need to differentiate ports by using addresses. Therefore, to
communicate with the right port you need to communicate with the specified address.
EXAMPLE:
2 RVON-I/O units are connected to the same Zeus System (RVON-I/O A and RVON-I/O B)
RVON-I/O A is connected to Zeus ports 1 and 2 on RVON-I/O ports 1 and 2.
RVON-I/O B is connected to Zeus ports 3 and 4 on RVON-I/O ports 1 and 2.
Because the Zeus cannot differentiate either of the RVON-I/O ports 1 and 2, it is necessary to adding an address to the ports:
RVON-I/O A port 1 set to 1 (set panel 0, poll ID 1)
port 2 set to 2 (set panel 1, poll ID 2)
RVON-I/O B port 1 set to 3 (set panel 0, poll ID 3)
port 2 set to 4 (set panel 1, poll ID 4)
If you are using Cronus or AIO-16 with RVON-I/0 in Remote mode for keypanels, you will still have to set a panel poll ID.
This is because the RVON-I/O has a default panel poll ID of 0 (zero). This must be changed to a non-zero number.
NOTE: Make sure to set the panel poll ID to 0 when trunking in Remote Mode. Doing this will ensure the RVON-I/O
will not respond to polls as a keypanel.
If the RVON-I/O in local mode is directly connected to a keypanel, the panel poll ID does not have to be set. The RVON-I/O
through polling will discover the address of the keypanel.
NOTE: If you are getting audio, but cannot see the alphas on the keypanels, verify the set panel ID is set correctly.
If you connect an RVON-I/O in Local mode to an intercom serially, you must NOT connect the data lines.
TABLE 15. All Keypanel Mode GPI/O assignments
LOCAL
GPI/O
RVON-I/O GPI/O
HARDWARE PORT
GPI/O 9 DB-25 Port 1
GPI/O 9 DB-25 Port 2
GPI/O 9 DB-25 Port 3
GPI/O 9 DB-25 Port 4
GPI/O 9 DB-25 Port 5
GPI/O 9 DB-25 Port 6
GPI/O 9 DB-25 Port 7
GPI/O 9 DB-25 Port 8