Power Over Ethernet (PoE) Operation for the Series 5300xl Switches
Configuring PoE Operation
1. Use the walkmib pethPsePortType.< slot-# > command to determine the
MIB-based port number for the port to which you want to assign a
Configured Type identifier. On the 5300xl switches the slot numbering is as
follows:
Slot Slot Number
Used in the MIB
A 1
B 2
C 3
D 4
E* 5
F* 6
G* 7
H* 8
*5308xl only.
Note that in the MIB, 26 port numbers are assigned to each slot designa-
tion. Thus, for example, with PoE modules in slots “A” and “B”, the actual,
corresponding port numbers will be 1-24 and 27-50, respectively. (The port
numbers “25”, “26”, “51”, and “52” are reserved.)
2. Use the setmib pethPsePortType.< slot-# >.< port-# > -D < identifier-string >
command to configure the identifier you want for a specific port.
For example, suppose that you have a PoE xl Module installed in slot B and
want to assign the identifier “Wireless-1” to port 1 in this slot. To do so, you
would use the following commands: