RTS DV-3400 Informações Técnicas Página 277

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 276
Access Controller xl Module for the Series 5300xl Switches
Configuring the Access Controller xl Module
From the CLI command prompt at the global configuration level, enter
ProCurve (config) #access-controller <slot-id> client-ports <port list>
where
<slot-id> is the slot letter where the module is installed.
<port list> is the switch port(s) to be used as downlink client ports.
For example:
ProCurve (config)# access-controller b client-ports a2,a6
assigns two downlink client ports and two new client VLANs (see Figure 12-
12-5). BDP, the downlink port for the module in slot B, is a tagged member of
both client VLANs.
ProCurve Switch 5308xl(config)# access-controller b client-ports a2,a6
ProCurve Switch 5308xl(config)# access-controller b
ProCurve Switch 5308xl(access-controller-B)# show vlans
Downlink:
VLAN ID VLAN Name Ports
2000 VLAN2000 A2,BDP
2001 VLAN2001 A6,BDP
Uplink:
VLAN ID VLAN Name Ports
1 DEFAULT_VLAN A1,A3-A5,A7-A24,BUP
ProCurve Switch 5308xl(config)# show vlans 2000
Status and Counters - VLAN Information - Ports - VLAN 2000
802.1Q VLAN ID : 2000
Name : VLAN2000
Status : Port-based
Voice : No
Port Information Mode Unknown VLAN Status
---------------- -------- ------------ --------- -
A2 Untagged Disable Down
BDP Tagged Disable Up
Figure 12-5. Configuring A Downlink Client Port